"electrical control equipment"
3 contactor 3P 4P 9A~95A 115~410A AC-3 AC-1 24V 110V 230V 380V de la CA de 1Phase LC1D
Schneider Electric LC1D AC Contactor 3P, 4P 9A~95A,115~410A,AC-3 AC-1 24V,110V,230V,380V Characteristic • Current range 09~620A; • AC, DC control coil is optional (DC coil to 38A); • Different types of starters are available: standard motor start contactors, reversible contactors, star-delta ...
Componentes modulares de la baja tensión del contactor de las TIC Acti9 1-4 poste 230V/400V 16 25 40 64 100A
Schneider Electric iCT Acti9 Modular Contactor 1,2,3,4 Pole 230V/400V Home or Industrial Use 16,25,40,64,100A IEC61095 characteristic Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class ...
Contactor termal de la retransmisión de la sobrecarga del contactor del motor de CA de LRD10C LED35C que fija 4~6A actual 30~38A
Schneider Electric LRD10C, LED35C Thermal Overload Relay For Contactor Setting Current 4~6A, 30~38A, 400V IEC947-4-1 characteristic • Manual/automatic reset • Pre-wired components • Independently mounted terminal block • Remote electrical reset • 45mm wide to 18.5Kw, 55mm wide from 15Kw to 30Kw, can ...
SPD protector de sobretensiones de 3 fases, dispositivos de protección contra sobrecargas nacionales 1 2 3 4 poste 230V/400V Imax20 40 65kA
Schneider Electric iST Surge Protection Device SPD 1,2,3,4 Pole 230V/400V Home or Industrial Use Imax=20,40,65kA Characteristic * IEC test category: Class II test (8/20us) * Compliance with standards: GB 18802.1 * Maximum sustainable operating voltage Uc: 340V * Maximum discharge current Imax: 65/40...
Metro multifuncional de la CA 1A 5A Digitaces, 380/400V 3 interfaz del metro de poder de la fase RS485
Chint PD666-S4, PD7777-S4 series digital multi-functional meter 3 380/400V phase with RS-485 communication interface PD666-S4 series three phase digital multi-functional meter Summary&application: PD666-S4 series three phase digital multi-functional meter is designed for the demand of power ...
CA neutral 10A de la retransmisión de protección del fracaso RV8-03~08
RV8-03~08 AC 3 Phase Voltage Controller Phase Sequence and Failure Protection Relay 10A General Applications -Control for connection of moving equipment(site equipment,agricultural equipent,refrigerated trucks). -Control for protection of persons and equipment against the consequences of reverse ...
1 2 3 dispositivo de protección contra sobrecargas de 4 postes SPD, fase industrial del protector de sobretensiones 3 1 fase 230V/400V
Chint Over-voltage Under-voltage Protection Relay 230V/400V Home or Industrial Use in 1-phase or 3-phase General NU6-II series surge protector is suitable for AC 50Hz, rated voltage 230V/400V three-phase power distribution and control system, meets SPD level test, used to suppress transient ...
Fase del dispositivo de protección contra sobrecargas de los componentes de la baja tensión del IEC 61643 SPD 1or 3
Chint NXU-II Surge Protection Device SPD 1,2,3,4 Pole 230V/400V Home or Industrial Use in IEC 61643 General NUX-II series surge protector is suitable for AC 50Hz, rated voltage 230V/400V three-phase power distribution and control system, meets SPD level test, used to suppress transient overvoltage ...
Componentes modulares 1 de la baja tensión del contactor de la CA 2 3 4 poste 20A 25A 40A 63A 230V/400V
Chint NCH8 Modular AC Contactor 1,2,3,4 Pole 20A,25A,40A,63A 230V/400V Home or Industrial Use IEC 61095 General Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class IP20B (terminal), ...
1 3 4 modulares contactor de la CA de 2 postes, IEC casero 61095 del contactor 20A 25A 40A 63A 230V/400V de la CA
NCH8 1,2,3,4 Pole 20A,25A,40A,63A 230V/400V Modular AC Contactor Chint Home or Industrial Use IEC 61095 General Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class IP20B (terminal), ...
La CA de CJX2-N que invierte el contactor, 3 organiza la inversión del contactor 3P 4P 9A~95A AC-3 AC-1
Chint CJX2-N AC Reversing Contactor 3P, 4P 9A~95A 1810, 2510, 3210, 6511, AC-3 AC-1 Coil Voltage 24V,110V,230V,380V characteristic • Current range 09~95A; • AC, DC control coil is optional (DC coil to 38A); • Different types of starters are available: standard motor start contactors, reversible ...
Metro análogo del factor de poder de la frecuencia de los componentes 600V 50A de la baja tensión del indicador del panel
Chint 42L6, 6L2 series analog panel pointer meter ammeter, voltmeter, Frequency, Power meter and Power factor meter 42L6, 6L2 series analog meter/panel meter/ pointer analog meter: Introduction: 42L6, 6L2 series instrument consists of measuring circuit, measuring mechanism and indicating device, ...